KESSEL

Pipes with Socket
KESSEL OD I d1 S1 D t Kg/m
332020009 32 3000 32 2 43 41 0.185
52099903
42030001
32020001
50 750
1500
3000
50
50
50
1.8
1.8
1.8
64
64
64
58
58
58
0.297
0.297
0.297
42030001
32020002
75 1000
3000
75
75
1.9
1.9
89
89
61
61
0.484
0.484
42020002
32020003
32020004
32020004
110
160
160
1000
3000
6000
3000
110
110
160
160
2.7
2.7
4
4
128
128
174
174
72
72
85
85
1.008
1.008
1.9

1.9

Pipes with Socket
KESSEL OD I d1 S1 D t Kg/m
332020009 32 3000 32 2 43 41 0.185
52099903
42030001
32020001
50 750
1500
3000
50
50
50
1.8
1.8
1.8
64
64
64
58
58
58
0.297
0.297
0.297
42030001
32020002
75 1000
3000
75
75
1.9
1.9
89
89
61
61
0.484
0.484
42020002
32020003
32020004
32020004
110
160
160
1000
3000
6000
3000
110
110
160
160
2.7
2.7
4
4
128
128
174
174
72
72
85
85
1.008
1.008
1.9

1.9

Bend with inspection

Dn α Z1 Z2 h Kg
75 87.5° 43 36 96 0.158
110 87.5° 57 61 133.0 0.262

Double Branch

Dn α Z1 Z2 Z3 L Kg
75/75/75 45° | 87.5° 28 | 36 59 | 44 59 | 44 153 | 140 0.190 | 0.197
110/75/75 45° | 87.5° 2 | 35 118 | 62 109 | 46 177 | 152 0.41 | 0.355
110/110/110 45° | 87.5° 40 | 53 85 | 64 85 | 64 201 | 187 0.530 | 0.363

Branch with inspection access

Dn α Z1 Z2 Z3 L Kg
75/75 87.5° 36 44 44 140 0.216
110/50 87.5° 27 59 30 122.0 0.337
110/75 87.5° 35 62 64 186 0.417
110/110 87.5° 57 61 61 185.0 0.383

Double Socket

Dn h I Kg
32 89 1.0 0.018
50 112 2.2 0.041
75 118 2.2 0.070
110 140 2.6 0.170

Elbow 160 mm °45

Dn d1 L L1 S α Kg
160 160 229 90 4 45° 0.605

Branch

Dn α Z1 Z2 Z3 Kg
32/32 45° | 87.5° 92.0 | 81.0 39 | 20 39 | 20 0.033 | 0.031
50/50 45° | 87.5° 130.0 | 114.9 61 | 29 61 | 29 0.092 | 0.080
75/50 45° | 87.5° 134.0 | 118.0 79 | 42 74 | 30 0.115 | 0.115
75/75 45° | 87.5° 168.0 | 142.0 91 | 43 91 | 43 0.115 | 0.142
110/50 45° | 87.5° 148.0 | 122.0 104 | 59 91 | 30 0.220 | 0.205
110/75 45° | 87.5° 175.0 | 152.0 116 | 60 109 | 44 0.265 | 0.235
110/110 45° | 87.5° 266.0 | 185.0 133 | 61 133 | 61 0.375 | 0.310

Plugs

Dn h Kg
50 39 0.013
75 39 0.034
110 46 0.066

Inspection Pipes

Dn I Kg
50 115 0.075
75 142 0.145
110 185 0.330

Reduction Pipes

Dn d1 Z1 L Kg
50/32 50.1 14 68 0.043
50/1 50.1 14 68 0.043
50/40 50 11 66 0.033
75/50 75 20 78 0.054
110/50 110 39 105 0.115
110/75 110 25 91 0.122

Socket 160 mm

Dn L L1 S Kg
160 184 90 4 0.390

Centric Reducer 110 / 160 mm

Dn d1 L L1 S Kg
160/110 160.1 215 90 4 0.380

Elbow 160 mm °45

Dn d1 L L1 S α Kg
160 160 229 90 4 45° 0.605

Elbow 160 mm °87.5

Dn d1 L L1 S α Kg
160 160 189 90 4 87.5° 0.610

Tee 160 mm 45°

D d1 L L1 S α Kg
160/110 160 366 100 4 45° 0.755
160/160 160 437 100 4 45° 1.100

Tee 160 mm °87.5

Dn d1 L L1 S α Kg
160/110 160 320 100 4 87.5° 0.640
160/160 160 370 100 4 87.5° 0.805

Bend 87.5

Dn α Z1 Z2 h Kg
32 87.5° 19 16 60 0.021
50 87.5° 27 31 89.5 0.050
75 87.5° 39 43 105.0 0.093
110 87.5° 57 61 133.0 0.230

Kessel Polypropylene Drainage Solutions

A. Introduction

EGIC produces push-to-fit drainage system made of polypropylene. This range of pipes, fittings and floor drains ensures ease of assembly and installation due to special seal plugs that tightly grip the pipes when they are inserted into the fitting sockets. The Pipes are made of polypropylene (PP) hot water resistant and they have also stabilized light sensitivity. Our range has sizes starting from 50mm – 160mm with an average Pipes Length 3 meters straight length and they stand out with the Color Grey RAL 7037.

B. The Advantages of Kessel Push-Fit Drainage System are:

  • The speed of making a connection with push-fit fittings where user can quickly cap or repair
  • Push-fit fittings are available in various sizes for different kinds of applications
  • Push-fit fittings are easily removed so they can be repositioned as needed without specialized tools
  • Plastic pipe with light weight, high flexibility, anti-leakage and chemical resistant

C. Installation Tips

  • Pipes, fittings and floor drains are connected by push-fit sockets and sealed tight with sealing ring.
  • Pipes can be easily cut to fit any length, chamfered and burned, connected and fixed in position.
  • In horizontal lines, the spacing of pipe clamps must not be more than ten times the outer diameter of the pipe. In vertical lines, spacing should not more than 1 meter (maximum 2 meters)
  • If the floor is covered with asphalt mastic, exposed pipe should be protected with heat-insulating material.
  • When Kessel pipes are laid in concrete, the socket gaps should be sealed with adhesive tape in order to prevent penetration of cement grout.